THE AVIATION SUPERSTORE FOR ALL YOUR AIRCRAFT & PILOT NEEDS | 877-795-2278
Thumbs 1
Thumbs 1

EGT Probe Kit A200-Tec25

$272.95/Each
Quantity
Add to Wishlist
Part# 10-04800
MFR Model# A200-TEC25

Overview

The A200-TEC25 is a Type-K ungrounded, fast response EGT thermocouple probe kit that will fit an exhaust with an outside diameter of 1 5/8" to 2 1/2". This probe will fit most Continental and Lycoming installations. Using an Inconel 600 sheath these probes have been designed and tested for continuous operation exceeding 2200ºF! Short-term exposures to higher temperatures are also possible. The insulation shield is a non-vitrified high purity magnesium oxide (MgO). Superior resistance to oxidation attack results from a tenacious and protective high temperature film that does not affect the stability of the thermocouple alloys. This film permits the sensor to be used at ultra-high temperatures for prolonged periods with improved accuracy over other available sheath materials.

The probes are supplied with a 90º insertion bend but this can be reformed in the field based upon the specific installation.

The probe is fused to the thermocouple conductor in a precision transition junction that protects the connection under all environmental conditions.

Finally the measured potential is carried to the instrument using high temperature Teflon™ insulated thermocouple wire that can endure temperatures up to 500ºF.

The connectors have a simple snap connection mechanism that allows easy removal and reattachment while retaining complete thermocouple junction integrity.

When installed in accordance with the approved instructions and as part of a qualified instrument system, this thermocouple is STC'd as a primary replacement.

For use with all Aerospace Logic exhaust gas instruments.

Kit Includes:

  • One EGT probe with 4' twisted shielded leads and male shielded thermocouple connector
  • One 2 1/2" aircraft grade 316 stainless steel ring clamp
  • One Female polarized and shielded connector for connection to instrument harness
  • Frequently Purchased With
  • Customers Also Viewed

Reviews

We have has tow out of four of these probes fail at the transition connection between the sheathed probe and the flexible cable. We replace the first on at out cost within 100 hours and two years after installation. We sent the first probe back to Aerospace Logic for analysis and their suggestion that they might be able to get their supplier to root cause and replace the probe. In the end they did nothing. Now less than 50 hours later a second probe has failed. The instrument is great, the quality of the probes is less than stellar!

Philip S
November 17, 2017

Q&A

Please note, Aircraft Spruce Canada's personnel are not certified aircraft mechanics and can only provide general support and ideas, which should not be relied upon or implemented in lieu of consulting an A&P or other qualified technician. Aircraft Spruce Canada assumes no responsibility or liability for any issue or problem which may arise from any repair, modification or other work done from this knowledge base. Any product eligibility information provided here is based on general application guides and we recommend always referring to your specific aircraft parts manual, the parts manufacturer or consulting with a qualified mechanic.

View in Catalog

View Image View in Catalog